Introduction: Automatic signalling is used by most railways throughout the world to prevent two trains from travelling toward each other on a single line and to maintain a safe distance for a train following behind, should the lead train come to a stop for any reason. The SMRH Automatic signal packs provide the realism of signals that change from green to red as a train travels past them and sets up simulated block signalling. Similar circuitry is also used to activate level crossing alarms realistically.

The principal operation of the auto circuits is the special latching relay. The relay is latched and unlatched by track detectors that are light sensitive. As a train passes over them, the shadow created triggers the relay.

Automatic Signal Circuit: Part No.ASC contains the detectors and circuit board to operate any of the HMA 2 colour series signals in all gauges. These include the 2 Aspect or 2 Colour Single Searchlights. Voltage input is either 15-18VAC or 12VDC. This circuit is designed to operate 2 signals facing the same direction, example double track main line where trains are consistently travelling in the same direction toward the signal. For use on single lines or point to point running, seeing the add on module DOM next. 

Dual Over-ride Module: Part No.DOM dual over-ride module is designed for use with the ASC circuits to facilitate reverting signals to red when trains are run opposed to the signals. The DOM circuit monitors track polarity to determine the train direction. The track polarity monitoring function is fully automatic for DC power control. For DCC, a manual train direction switch is required.

Protect the Section Signal Circuit: Part No.PSC This circuit protects a section of single track between two stations by having up to 2 x 2 colour signals govern the departure at each station. The 2 Aspect type or 2 Colour Single Searchlights are suitable. The circuit also detects track polarity to display correct signal aspects. Voltage input is either 15-18VAC or 12VDC.

Protect the Section - Add Signal module and Add Detector module: Part No.PSAS and PSAD to allows dual signals to function as departures from both the main line and loop line. The modules looks at the direction of the points via a contact switch to cycle the correct detector and signal. Power input is from the Protect the Section Signal Circuit. The PSAS pack does not include the additional signal required.

Yard Departure Pack: Part No.YDP circuit provides the automation of a green departure ground light lit up only when the points ahead are correctly set and the correct polarity is applied for a train to depart toward the signal. For reverse movements on the road or the points not set, the ground light remains at red. The circuit requires connection to an accessory switch activated by the points ahead of the departure signal. The track polarity function is fully automatic for DC power control. OO/HO gauge LED yard light included. Voltage input either 15-18VAC or 12VDC.

Level Crossing Module: Part No.LCM contains the detectors and circuit board  to operate any of the HMA Crossing Alarms and Flasher. This circuit provides the realism of activating level crossing alarms automatically as a train approaches from either direction. The circuit board outputs 12 Volts DC to switch the flasher unit on or off. The relays latch and unlatch by light sensitive track detectors. The circuit also monitors track polarity to determine which sensor to trigger the flasher unit for the direction of the train. The track polarity function is automatic for 12VDC power control. Voltage input: either 15-18VAC or 12VDC.

Level Crossing Add Detector module: Part No. LCMAD module is for use in conjunction with the LCM to provide the facility to install an additional detector on a loop track that either joins the main line before or just after the crossing. The module requires connection to an accessory contact switch activated by the loop to main line points to enable the LCMAD to determine which detector is required to activate the LCM.